HIGH VOLTAGE: HAZARD OF ELECTRICAL SHOCK. DISCONNECT INCOMING POWER BEFORE WORKING ON THIS.
WARNING: This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar the hazards involved. Failure to observe this precaution could result in bodily injury.
|
ESP32-S3 based Home heating system controller.
Designed to use with ESPHome for:
- Maximum flexibility
- Ease of programming
- Seamless integration to Home assistant.
External interfaces:
- 6x PT100 3 wire RTD temperature sensor inputs.
- Integrated AC solid state relay outputs:
- 4x smal current output pairs for actuators (mixing valves).
- 5x outputs for inductive loads up to 2A.
- Uart connection for Nextion or other HMI display.
- Button with RGB led connection.
- Analog pressure sensor connection (With signal output up to 5V).
- 1wire bus for additional sensors.
- 2x dry contact inputs. For floor demand or other functions (internaly pulled to 12V).
Wire connectors:
- For low voltage connection and sensors:
- Dieran DA803 or other 3.5mm pitch.
- For High voltage AC connection:
- Dieran DA806 or other 5mm pitch.
External connection diagram: