LU-MOD quad latching points interlock

STDLU-MOD quad latching points interlock

tag

63
0
0
0
Mode:Full

License

CERN Open Hardware License

Creation time:2023-12-30 21:24:53Update time:2024-01-03 17:01:00

Description

Circuit card for connecting modular model railways depicting the London Underground built to the LU-MOD standard.

 

    • Connect up to four outputs that require protection for either normal or reverse settings (e.g. points)
    • Connect up to four momentary contact levers or push-buttons to control the outputs – the output will only be triggered if the conditions should be met.
    • Connect up to 3 inputs for each output, each of which must be active (at 5v) before the output is set either normal or reverse.
    • Connect up to a further 3 inputs for each output, none of which may be active (at 5v) before the output is set either normal or reverse.
    • Unused inputs can be bypassed by connecting them directly to the 5v power supply (enabling inputs) or not connecting them (disabling inputs).
    • Requires 1x 5v 1A power supply
    • Size: 100mm x 100mm