Your EasyEDA usage duration is brief. In order to avoid advertising information, this action is not supported at present. Please extend your EasyEDA usage duration and try again.
Editor Version×
recommended
Pro Edition
Brand new interactions and interfaces
Smooth support for design sizes of over 3W
devices or 10W pads
More rigorous design constraints, more
standardized processes
For enterprises, more professional users
Std Edition
Easy to use and quick to get started
The process supports design scales of 300
devices or 1000 pads
Supports simple circuit simulation
For students, teachers, creators
Ongoing
STD
SparkFun Thermocouple Breakout - MAX31855K
SparkFun Thermocouple Breakout - MAX31855K
Project tags
License
License:
Mode:
Mode
Editors' pick
Editors' pick
2.2k
0
0
2
Update time:
2021-04-11 15:08:58
Creation time:
2016-07-15 02:56:26
Description
Description
![enter image description here][1]
![enter image description here][2]
**Description**: The SparkFun MAX31855K Thermocouple Breakout is a simple 14-bit resolution, SPI-compatible, serial interface thermocouple digitizer that makes reading a wide range of temperatures possible. A thermocouple works by taking two wires made of dissimilar metals, connecting them at the two ends, and making a temperature gradient between one end and the other (a ‘hot’ end and a ‘cold’ one). Once this is achieved, a voltage potential is formed and current flows. The SparkFun Thermocouple Breakout takes a standard Type-K thermocouple in one end, digitizes the temperature measured and sends that data out the other end via a SPI interface, thereby interpreting the data and translating it for you to read!
With the SparkFun Thermocouple Breakout, the thermocouple’s hot junction can be read from -200°C to +700°C with an accuracy of ±2°C while the cold junction, inside the MAX31855K, can only range from -20°C to +85°C while maintaining ±2°C accuracy. The MAX31855K constantly measures the temperature of the cold junction using an internal temperature-sensing diode. The MAX31855K requires a power source from +3.0V to +3.6V (+3.0V nominal) and only draws 1.5mA maximum.
The Thermocouple Breakout is designed to accept a standard thermocouple connector, for convenience and compatibility with probes you may already own. These connectors aren’t necessary, and you could solder a thermocouple directly into the through holes labeled ‘+’ and ‘-’. If you decide to solder the thermocouple directly to the breakout board, it is recommended that the thermocouple be mounted for strain relief to avoid breaking the thin wires. Notches for a zip-tie or wire wrapping have been provided in the PCB opposite the header for this purpose.
**Features**:
14-bit Resolution
SPI-Compatible, Serial Interface
-200°C to +700°C Temperature Reading with ±2°C Accuracy
3.0V to 3.6V (+3.0V nominal) Required
Accepts Type-K Thermocouple
For more detail and Documents, Please visit: http://www.sparkfun.com/products/13266
[1]: /editor/20160717/578ba80f9258a.png
[2]: /editor/20160717/578ba8143905d.png
Forked project will be set private in personal workspace. Do you continue?
Clone
Project
The Pro editor is about to be opened to save as. Do you want to continue?
private message
Send message to sparkfun
Delete
Comment
Are you sure to delete the comment?
Report
SparkFun Thermocouple Breakout - MAX31855K
No Profile
Announcer: SparkFun
Creation time: 2016-07-15 02:56:26
Published time:
2021-04-11 15:08:58
*
Report type:
Please select report type
*
Report reason:
Please fill in the reason for your report and the content is 2-1000
words
*
Upload image:
+
Upload image
*
Email address:
Please fill in your email address
Report
*
Report type:
Please select report type
*
Report reason:
Please fill in the reason for your report and the content is 2-1000
words
*
Upload image:
+
Upload image
*
Email address:
Please fill in your email address
Report
Submitted successfully! The review result can be viewed in the personal
center, review notification.
Kind tips
Your EasyEDA usage duration is brief. In order to avoid advertising information, this action is
not supported at present. Please extend your EasyEDA usage duration and try again.
Share
Project
Copy
Copy
Scan the QR code and open it on the mobile terminal